| Model |
TGE-250kN |
TGE-100kN |
TGE-50kN |
TGE-10kN |
TGE-5kN |
TGE-1kN |
TGE-500N |
TGE
-200N |
| Maximum test force |
250 kN |
100 kN |
50 kN |
10 kN |
5 kN |
1 kN |
500 N |
200 N |
| Test force measurement range (Note 1) |
0.1 N ~ 250 kN |
0.1 N ~ 100 kN |
0.1 N ~ 50 kN |
0.1 N ~ 10 kN |
0.1 N ~
5 kN |
0.1 N ~ 1 kN |
0.1 N ~ 500 N |
0.1 N ~ 200 N |
| Test space |
Tensile and Compression testing beneath the movable crosshead.
(An optional model is available allowing tensile testing above the movable crosshead.) |
| Loading method |
Constant-speed strain loading with high-accuracy AC servo motor and backlash-free precision ball screw |
| Crosshead speed/permissible test force |
Within the max. test force over the entire speed range. |
| Test force range |
Choice of ×1 (AUTO) and ×100 if load cell rated output is 3 mV/V; ×1 (AUTO) if load cell rated capacity is 20 N or less.
When ×1 (AUTO) is set: test force increase/decrease, full scale display,
and automatic switching of decimal point position and display units |
| Test force measuring accuracy |
±1% of indicated value in range 1/1 to 1/500 of load cell capacity for both tensile and compression (A high-accuracy model with ±0.5% of indicated value is available as an option.) |
| Applicable standard |
JIS B 7721 Class 1 or Class 0.5 and ISO7500-1 Class 1 or Class 0.5 |
| Effective test width (Note 2) (mm) |
600 |
600 |
420 |
420 |
| Cross head stroke (mm) |
1 550 |
1 350 |
1 015 |
1090 |
| Maximum mounting space (Note 3) (mm) |
1 690 |
1 555 |
1 165 |
1 185 |
| Tensile stroke (Note 4) (mm) |
620 |
850 |
470 |
710 |
815 |
860 |
890 |
910 |
| Crosshead speed |
0.1, 0.5, 1 to 500 (can be set in 1 mm/min increments) |
| Crosshead speed accuracy |
±0.5% of speed setting or ±0.0025 mm/min, whichever is larger |
| Speed setting method |
Manual: Numeric input via control panel (0.1, 0.5, 1 to 500 set in 1 mm/min increments)
When using data processing software: Automatically set in accordance with test conditions created. |
| Manual speed |
3 speeds (HIGH/MIDDLE/LOW); each speed freely settable |
| Test mode |
Single and cycle (combination of test force and position) Optional: Creep, stress relaxation, automatic loading |
| Display |
5-digit digital display ±99,999, able to display peak or rupture test force, position: 5 1/2 digital display ±1999,999 |
| Standard functions |
| Load Cell model and capacity. |
: |
Auto adjust |
| Load Cell span |
: |
Auto set for tension/compression. |
| Load Cell Zero point |
: |
One push |
| Position reset |
: |
One push |
| Sample rupture detection |
: |
Selectable from stop, reverse and ignore |
| Rupture sensitivity |
: |
Set as desired to 0.04 % to 99.00 % of test force |
| Test condition registration function |
: |
10 conditions |
| Test force & position analog output |
: |
0 V to 5 V DC (with scaling function) |
| Interface |
: |
Conforms to USB 2.0/1.1 standard (B-type connector) |
|
| Options |
| Chuck adapter |
: |
Lower chuck mounting adapter for tensile testing |
| Load Cell |
: |
for tensile/compression type (with universal joint, connecting pin, and compression plate)
------------
for tensile type (with universal joint and connecting pin)
-------------
for compression type (with compression plate) |
| Test jig |
: |
Former jig is attachable. |
| Displacement measuring function |
: |
Strain input type |
| Test machine stand |
: |
TGE-M01 (for sitting work),
TGE-M02 (for standing work) |
| Contact I/O |
: |
Use for TGE-I/O air chuck cover |
| Data processing software |
: |
Standard (tensile/compression/bending), peeling, cycle (one way, both ways),
stress relaxation |
|
External dimensions
(W x H x D) (mm) |
1 400
x 2 450 x 894 |
1 221
x 2 192 x 720 |
900
x 1 522 x 490 |
660 x 1 592 x 503 |
| Approximate weight (kg) |
1 200 |
900 |
300 |
80 |
| Power supply voltage, Frequency |
3-phase AC200 V±20 V, 50/60 Hz |
Single phase AC100 V ~ 115 V, 50/60 Hz |
| Power consumption |
7 kW |
5 kW |
1.5 kW |
200 W |
| Operating temperature /humidity range |
Temperature 5 ℃ ~ 40 ℃,
Humidity 20 % ~ 80 %RH (with no condensation) |
- Note 1: The test force measurement range varies depending on the rated capacity of the load cell used.
Note 2: Testing machines are available with large effective width for models with maximum test force of 50 kN, 100 kN or 250 kN.
Note 3: Models are available with extended stroke.
Note 4: Tensile testing stroke is for maximum test force capacity load cell with the (optional) chuck mounted.
|